El kit de accesorios para osciloscopio Autel MaxiSYS MSOAK funciona con MaxiFlash VCMI Ultra EV, Ultra, MS919 y MP408, pinza amperimétrica CA/CC de 65 A/650 A, sonda de enchufe en bobina, cable de extensión HT, clip de batería de 2 x 2 piezas
€225.00
- Oficiales 100% originales Herramientas Autel Launch ThinkCar
- Libre de impuestos de importación (almacén europeo, estadounidense, británico, australiano y ruso)
- Envío rápido 3-5 días DHL o UPS
- Actualizaciones gratuitas de por vida
- Descripción
- Envío
- GARANTÍA Y ACTUALIZACIONES
- Valoraciones (0)
Descripción
Compatible with MSULTRA, Ultra EV, MS919 and MP408
Includes 65A AC/DC Current Clamp, 650A AC/DC Current Clamp
Includes Coil On Plug Probe, HT Extension Lead (2pcs) and Battery Clip (2pcs)
Incluye estuche de transporte
650A AC/DC Current Clamp Introduction:
When measuring AC or DC with the Current Clamp, you can connect it with a multimeter or an oscilloscope to directly read the current value without the need to make physical contact with the conductor, or to disconnect it for insertion through the probe. The Current Clamp measures a maximum current of 650A, with a frequency up to 400Hz. It works with jaws which open to allow clamping around an electrical conductor. After linking it with a multimeter or an oscilloscope, push down the zero adjustment knob on the clamp until the multimeter or osilloscope reads zero.
65AAC/DC Current Clamp APPLICATION PROCEDURE:
1. Connect the BNC connector of the clamp to the input of a multimeter or an oscilloscope with an input impedance of at least 10k ohms.
2. When the current is no greater than 20A, set the current clamp to the range of 1mV/10mA, otherwise to 1mV/100mA. The green LED lights, indicating that the clamp is
switched on.
3. Before measuring DC, please push down the zero adjustment knob on the clamp until the multimeter or oscilloscope reads zero. When using an oscilloscope, set DC coupled mode to measure DC.
4. Clamp the jaws around the electrical conductor.
5. When the current clamp is set to 1mV/10mA, the actual current value is ten times of the measured data whose unit is mV. For example, the measured data is 10 mV and the actual current is 10×10= 100mA.
6. When the current clamp is set to 1mV/100mA, the actual current is one hundred times of the measured data whose unit is mV. For example, the measured data is 5 mV and the actual current is 5x 100=500mA.
Coil On Plug (COP) Probe Feature:
COP Probe can catch the ignition waveform of automobile engine easily. The ignition waveform is a window, through which we can see what happened in the engine combustion chambers. It determines whether the ignition plug needs to be replaced or cleaned.
● It can be used with normal oscilloscope. Special anti-interference design, high accuracy of measurement.
● Ergonomic design, can be arbitrary curved.
● Highlight LED which is convenient to operate at night or in dark condition.
Warning:
● To avoid injury, keep the probe away from moving parts, such as the alternator drive belt and cooling fans.
● To present electric shock, do not use if the probe’s sensor plate’s insulation shows signs of damage.
1 año de garantía
Actualizaciones: 1 año de actualización gratuita
Solo los usuarios registrados que hayan comprado este producto pueden hacer una valoración.
Valoraciones
No hay valoraciones aún.